Extraction table for welding work, worksurface 1400 x 900 mm

Item number: 173299W

  • Direct extraction of harmful substances from the workplace. The workstations have an integrated air supply and extraction device. With the air supply device, the air flow is directed diagonally from the lower and upper edges of the workstation into the work area, so that the user is constantly in a shielded air zone. The pollutants cannot break through this wedge of clean air and therefore remain in the rear part of the workstation
  • Due to the aerodynamically shaped baffles and the semi-open design, the air containing pollutants is optimally captured and extracted, even at low air volume flows, by means of the Coanda effect achieved.
  • Workstations can be connected to a central extraction unit or can be set up as individual tables with a decentralised extraction system. Depending on the situation, further fans and filter systems are required for this purpose
  • Extraction system for workplaces, incl. welding curtains and air supply unit
  • The unit is quiet except for the suction noise, which depends on the air extraction fan. The air supply fan is below 50 dB(A)
  • Delivery includes fresh air fan. This is supplied mounted on the workstation. The fan takes the air from the immediate vicinity of the workstation
  • Worktop in 5 mm steel
  • Connection cable with safety plug, approx. 5 m long
  • Workplace light with adjustable angle, IO 65, 230 Volt
  • Add on switch with socket, 230 Volt, side curtain rails in stainless steel
  • Height adjustable feet (mech. + 70 mm)
  • 2 x air inlet connection (DN 80), 1 x top air extraction connection (DN 200)
  • Incl. earth and earthing connection
  • Height adjustable feet (mech. + 70 mm)
  • Sturdy tubular steel design in powder coated grey, RAL 7035, rear wall and deflector plates in anthracite, RAL 7016
Full description
Jump straight to:
£5,442.00 Excl. VAT

Free shipping to Mainland U.K.

Shipping Time: > 5 weeks
We work hard to give you good advice.
Do you need help?
We work hard to give you good advice.
Free expert advice01952 811 991

Mon-Thu: 8:30am – 5:00pm
Fri: 8:30am – 4:00pm

New
SALE
bestseller
[[record.name]]
[[record.actionPrice]] [[record.price]] [[record.price]] Excl. VAT
Price on request
New
SALE
bestseller
[[record.name]]
[[record.actionPrice]] [[record.price]] [[record.price]] Excl. VAT
Price on request

Product description

  • Direct extraction of harmful substances from the workplace. The workstations have an integrated air supply and extraction device. With the air supply device, the air flow is directed diagonally from the lower and upper edges of the workstation into the work area, so that the user is constantly in a shielded air zone. The pollutants cannot break through this wedge of clean air and therefore remain in the rear part of the workstation
  • Due to the aerodynamically shaped baffles and the semi-open design, the air containing pollutants is optimally captured and extracted, even at low air volume flows, by means of the Coanda effect achieved.
  • Workstations can be connected to a central extraction unit or can be set up as individual tables with a decentralised extraction system. Depending on the situation, further fans and filter systems are required for this purpose
  • Extraction system for workplaces, incl. welding curtains and air supply unit
  • The unit is quiet except for the suction noise, which depends on the air extraction fan. The air supply fan is below 50 dB(A)
  • Delivery includes fresh air fan. This is supplied mounted on the workstation. The fan takes the air from the immediate vicinity of the workstation
  • Worktop in 5 mm steel
  • Connection cable with safety plug, approx. 5 m long
  • Workplace light with adjustable angle, IO 65, 230 Volt
  • Add on switch with socket, 230 Volt, side curtain rails in stainless steel
  • Height adjustable feet (mech. + 70 mm)
  • 2 x air inlet connection (DN 80), 1 x top air extraction connection (DN 200)
  • Incl. earth and earthing connection
  • Height adjustable feet (mech. + 70 mm)
  • Sturdy tubular steel design in powder coated grey, RAL 7035, rear wall and deflector plates in anthracite, RAL 7016

Technical data

VersionExtraction table for welding and soldering
MaterialSteel
SurfacePowder coated
ColourGrey
Total air supplied [m³/h]200
Total air extraction [m³/h]1500
Work area [W x D mm]1400 x 900
External dimensions W x D x H [mm]1600 x 1150 x 2400
ModelSL 1400
Weight [kg]220
Work surface height [mm]875
Protection category IPIP 65
Nominal voltage [V]230
Air extraction monitoringNo

Documents

173299DatasheetDEDownload

Customer reviews

We work hard to give you good advice.
Do you need help?
We work hard to give you good advice.
Free expert advice01952 811 991

Mon-Thu: 8:30am – 5:00pm
Fri: 8:30am – 4:00pm

Free delivery
Free delivery

to Mainland U.K.

Spare parts and maintenance service
Spare parts and maintenance service

Everything from one source: We offer a spare parts and maintenance service.

icon DENIOS warranty
DENIOS Warranty

up to 10 years

Use code UK10 at checkout and receive 10% off your order!*

*Cannot be combined with other promotions, discounts or other special prices. Does not apply to open quotations.