Item number: 274682W
The structural calculations for the technical room system are based on Eurocode 3 (EN 1993). The loads on the structure are measured according to Eurocode 1 (EN 1991-1-3) for a characteristic wind load qk,w = 0.585 kN/m² and a ground snow load sk = 2.5 kN/m². The structure is also designed for earthquake zone 3 according to EN 4149, EN 1998-1:2004.
Mon - Thu: 08:30 - 17:00 Fri: 08:30 - 16:00
The structural calculations for the technical room system are based on Eurocode 3 (EN 1993). The loads on the structure are measured according to Eurocode 1 (EN 1991-1-3) for a characteristic wind load qk,w = 0.585 kN/m² and a ground snow load sk = 2.5 kN/m². The structure is also designed for earthquake zone 3 according to EN 4149, EN 1998-1:2004.
Material | Steel |
Door version | hinged door |
Door design | 2 wing doors |
Door hinge | both sides |
Containment volume [l] | 1365 |
Surface | galvanized |
Dimensions (without attachments) W x D x H [mm] | 2900 x 1590 x 2060 |
Internal dimensions W x D x H [mm] | 2540 x 1315 x 1455 |
Colour | Grey white |
RAL Code | 9002 |
Secondary colour | Grey |
RAL Code 2 | 7043 |
Overall load capacity [kg] | 4000 |
Certification / certificate | DIBt (Z-38.5-293) |
Weight [kg] | 810 |
Capacity IBC / CP / EP / drum | 2 / 2 / 3 / 8 |
Mon - Thu: 08:30 - 17:00 Fri: 08:30 - 16:00