Item number: 274690W
The structural calculations for the technical room system are based on Eurocode 3 (EN 1993). The loads on the structure are measured according to Eurocode 1 (EN 1991-1-3) for a characteristic wind load qk,w = 0.585 kN/m² and a ground snow load sk = 2.5 kN/m². The structure is also designed for earthquake zone 3 according to EN 4149, EN 1998-1:2004.
The structural calculations for the technical room system are based on Eurocode 3 (EN 1993). The loads on the structure are measured according to Eurocode 1 (EN 1991-1-3) for a characteristic wind load qk,w = 0.585 kN/m² and a ground snow load sk = 2.5 kN/m². The structure is also designed for earthquake zone 3 according to EN 4149, EN 1998-1:2004.
Dimensions (without attachments) W x D x H [mm] | 6500 x 2944 x 2365 |
Internal dimensions W x D x H [mm] | 6240 x 2740 x 2100 |
Storage area [m²] | 17 |
Door version | hinged door |
Door design | 2 wing doors |
Insulation | optional |
Containment volume [l] | 2612 |
Colour | Gentian violet |
RAL Code | 5010 |
Length, external [mm] | 2944 |
Weight [kg] | 2310 |
Width, external [mm] | 6500 |
Load capacity [kg/m²] | 1000 |
Height, external [mm] | 2365 |
Installation location | Indoors and outdoors |