Fire-protected charging compartment for lithium-ion batteries WFP-X 10 Li-Ion Charge

Item number: 274978W

  • Ready-to-connect, fire-protected charging compartments from DENIOS offer a safe and efficient way to charge a large number of batteries simultaneously.
  • Tested and approved as a complete system with 90 minute fire protection (REI 90) from inside and outside.
  • Internationally, versions to meet country-specific legislation (e.g. REI 120).
  • Sockets can be realised either by chargers placed on shelves or by convenient wall-mounted charging rails with several sockets per socket.
  • Display of CO2 savings through the use of electric appliances compared to petrol-powered appliances.
  • Optional technical ventilation or air conditioning prevents heat build-up when charging the lithium batteries.
  • Interior and exterior lighting and signalling lights are also available.
  • Optionally expandable with IoT early warning system (DENIOS connect) and extinguishing technology.
  • Additional advantages: low entry height of 147 mm and precise roof drainage.

Structural analysis

The structural calculations for the technical room system are based on Eurocode 3 (EN 1993). The loads on the structure are measured according to Eurocode 1 (EN 1991-1-3) for a characteristic wind load qk,w = 0.585 kN/m² and a ground snow load sk = 2.5 kN/m². The structure is also designed for earthquake zone 3 according to EN 4149, EN 1998-1:2004. With additional equipment up to wind load zone 4 with terrain category I (qk,w = 1.064 kN/m²) or up to ground snow load sk = 5.86 kN/m².

Roof drainage

Roof drainage channels rain water to the frame running around the edge and drains it away on the short sides either to the left or the right.

Full description
We work hard to give you good advice.
Do you need help?
We work hard to give you good advice.
Free Expert Advice01952 811991

Mon - Thu: 08:30 - 17:00 Fri: 08:30 - 16:00

New
SALE
bestseller
[[record.name]]
[[record.actionPrice]] [[record.price]] [[record.price]] Excl. VAT
Price on request

New
SALE
bestseller
[[record.name]]
[[record.actionPrice]] [[record.price]] [[record.price]] Excl. VAT
Price on request

Product description

  • Ready-to-connect, fire-protected charging compartments from DENIOS offer a safe and efficient way to charge a large number of batteries simultaneously.
  • Tested and approved as a complete system with 90 minute fire protection (REI 90) from inside and outside.
  • Internationally, versions to meet country-specific legislation (e.g. REI 120).
  • Sockets can be realised either by chargers placed on shelves or by convenient wall-mounted charging rails with several sockets per socket.
  • Display of CO2 savings through the use of electric appliances compared to petrol-powered appliances.
  • Optional technical ventilation or air conditioning prevents heat build-up when charging the lithium batteries.
  • Interior and exterior lighting and signalling lights are also available.
  • Optionally expandable with IoT early warning system (DENIOS connect) and extinguishing technology.
  • Additional advantages: low entry height of 147 mm and precise roof drainage.

Structural analysis

The structural calculations for the technical room system are based on Eurocode 3 (EN 1993). The loads on the structure are measured according to Eurocode 1 (EN 1991-1-3) for a characteristic wind load qk,w = 0.585 kN/m² and a ground snow load sk = 2.5 kN/m². The structure is also designed for earthquake zone 3 according to EN 4149, EN 1998-1:2004. With additional equipment up to wind load zone 4 with terrain category I (qk,w = 1.064 kN/m²) or up to ground snow load sk = 5.86 kN/m².

Roof drainage

Roof drainage channels rain water to the frame running around the edge and drains it away on the short sides either to the left or the right.

Technical data

ModelWFP-X 10 Li-Ion Charge
Dimensions (without attachments) W x D x H [mm]4478 x 2784 x 2921
Internal dimensions W x D x H [mm]4040 x 2560 x 2500
Storage area [m²]10
Door versionhinged door
InsulationHeat insulation
Fire resistance90 minutes
120 minutes
Load capacity [kg/m²]1000
Containment volume [l]1450
Internal room height [mm]2500 mm
Weight [kg]3260

Documents

Service

We work hard to give you good advice.
Do you need help?
We work hard to give you good advice.
Free Expert Advice01952 811991

Mon - Thu: 08:30 - 17:00 Fri: 08:30 - 16:00

Menu
Loading ...
Log in
Added to basket
Fire-protected charging compartment for lithium-ion batteries WFP-X 10 Li-Ion Charge
Fire-protected charging compartment for lithium-ion batteries WFP-X 10 Li-Ion Charge
Item number: 274978W
Go to basket