Li-ion battery storage system POWER SAFE, EFP 1600, with fire protection

Item number: 274948W

  • The fire-rated solution for the safe operation of battery storage systems.
  • With classified fire protection from the inside and outside and therefore suitable for installation directly at the external wall of neighbouring buildings.
  • Integrated powerful storage system for very fast energy storage and release, optimised for permanent use in industry and commerce.
  • Individual adaptability to the required storage needs.
  • Tested, single-piece spill pallet with easily removable hot-dip galvanised grids (load capacity: 1000 kg / m²).
  • Fire protection panels with high insulation properties (thickness 100 mm, A class material, non-combustible).
  • Lockable, self-closing EI₂ 90-C fire-rated doors in accordance with EN 13501-2, tested in accordance with EN 1634-1
  • Surveillance and lighting technology - optionally also available with outdoor motion detector.
  • Structural analysis: to Eurocode 3 (DIN EN 1993) measured for a characteristic wind load with a dynamic pressure of qw = 0.585 kN/m² and a characteristic ground snow load of sk = 2.5 kN/m²; adequately dimensioned according to DIN 4149, EN 1998-1:2004 for earthquake zone 3. Available with additional equipment for up to wind load zone 4, terrain category I (qw= 1.064 kN/m²) and for up to ground snow load sk = 5.86 kN/m²

Structural analysis

The structural calculations for the technical room system are based on Eurocode 3 (EN 1993). The loads on the structure are measured according to Eurocode 1 (EN 1991-1-3) for a characteristic wind load qk,w = 0.585 kN/m² and a ground snow load sk = 2.5 kN/m². The structure is also designed for earthquake zone 3 according to EN 4149, EN 1998-1:2004. With additional equipment up to wind load zone 4 with terrain category I (qk,w = 1.064 kN/m²) or up to ground snow load sk = 5.86 kN/m².

Roof drainage

Roof drainage channels rain water to the frame running around the edge and drains it away on the short sides either to the left or the right.

Full description
We work hard to give you good advice.
Do you need help?
We work hard to give you good advice.
Free Expert Advice01952 811991

Mon - Thu: 08:30 - 17:00 Fri: 08:30 - 16:00

New
SALE
bestseller
[[record.name]]
[[record.actionPrice]] [[record.price]] [[record.price]] Excl. VAT
Price on request
New
SALE
bestseller
[[record.name]]
[[record.actionPrice]] [[record.price]] [[record.price]] Excl. VAT
Price on request

Product description

  • The fire-rated solution for the safe operation of battery storage systems.
  • With classified fire protection from the inside and outside and therefore suitable for installation directly at the external wall of neighbouring buildings.
  • Integrated powerful storage system for very fast energy storage and release, optimised for permanent use in industry and commerce.
  • Individual adaptability to the required storage needs.
  • Tested, single-piece spill pallet with easily removable hot-dip galvanised grids (load capacity: 1000 kg / m²).
  • Fire protection panels with high insulation properties (thickness 100 mm, A class material, non-combustible).
  • Lockable, self-closing EI₂ 90-C fire-rated doors in accordance with EN 13501-2, tested in accordance with EN 1634-1
  • Surveillance and lighting technology - optionally also available with outdoor motion detector.
  • Structural analysis: to Eurocode 3 (DIN EN 1993) measured for a characteristic wind load with a dynamic pressure of qw = 0.585 kN/m² and a characteristic ground snow load of sk = 2.5 kN/m²; adequately dimensioned according to DIN 4149, EN 1998-1:2004 for earthquake zone 3. Available with additional equipment for up to wind load zone 4, terrain category I (qw= 1.064 kN/m²) and for up to ground snow load sk = 5.86 kN/m²

Structural analysis

The structural calculations for the technical room system are based on Eurocode 3 (EN 1993). The loads on the structure are measured according to Eurocode 1 (EN 1991-1-3) for a characteristic wind load qk,w = 0.585 kN/m² and a ground snow load sk = 2.5 kN/m². The structure is also designed for earthquake zone 3 according to EN 4149, EN 1998-1:2004. With additional equipment up to wind load zone 4 with terrain category I (qk,w = 1.064 kN/m²) or up to ground snow load sk = 5.86 kN/m².

Roof drainage

Roof drainage channels rain water to the frame running around the edge and drains it away on the short sides either to the left or the right.

Technical data

External dimensions W x D x H [mm]5938 x 2878 x 3009
Door positionShort side
Door versionhinged door
Door design1-wing
Door hingeright
Fire resistance90 minutes
120 minutes
Internal room height [mm]2500 mm
Storage capacity [kWh]880 - 1280
Weight without storage [kg]4100
Weight [kg]4100

Compare with similar products

External dimensions W x D x H [mm]
5938 x 2878 x 3009  
1910 x 1980 x 2376  
3018 x 2784 x 2875  
4478 x 2784 x 2921  
8858 x 2878 x 3009  
Door position
Short side  
 
Short side  
Long side, middle  
Short side  
Storage capacity [kWh]
880 - 1280  
80 - 160  
240 - 480  
560 - 800  
1360 - 1600  
Weight without storage [kg]
4100  
1075  
2550  
3260  
5450  
Weight [kg]
4100  
1075  
2550  
3260  
5450  

Documents

We work hard to give you good advice.
Do you need help?
We work hard to give you good advice.
Free Expert Advice01952 811991

Mon - Thu: 08:30 - 17:00 Fri: 08:30 - 16:00

Use code UK10 at checkout and receive 10% off your order!*

*Cannot be combined with other promotions, discounts or other special prices. Does not apply to open quotations.