DENIOS Ltd
Audley Ave Enterprise Park
Nova House, Suite 1
Newport, Shropshire
TF10 7DW

Tel.: +44 1952 811991
Email: info@denios.co.uk
Internet: www.denios.co.uk

Li-ion battery storage system POWER SAFE, M, with fire protection

Item number: 274946W

  • The fire-rated solution for the safe operation of battery storage systems.
  • With classified fire protection from the inside and outside and therefore suitable for installation directly at the external wall of neighbouring buildings.
  • Integrated powerful storage system for very fast energy storage and release, optimised for permanent use in industry and commerce.
  • Individual adaptability to the required storage needs.
  • Tested, single-piece spill pallet with easily removable hot-dip galvanised grids (load capacity: 1000 kg / m²).
  • Fire protection panels with high insulation properties (thickness 100 mm, A class material, non-combustible).
  • Lockable, self-closing EI₂ 90-C fire-rated doors in accordance with EN 13501-2, tested in accordance with EN 1634-1
  • Surveillance and lighting technology - optionally also available with outdoor motion detector.
  • Structural analysis: to Eurocode 3 (DIN EN 1993) measured for a characteristic wind load with a dynamic pressure of qw = 0.585 kN/m² and a characteristic ground snow load of sk = 2.5 kN/m²; adequately dimensioned according to DIN 4149, EN 1998-1:2004 for earthquake zone 3. Available with additional equipment for up to wind load zone 4, terrain category I (qw= 1.064 kN/m²) and for up to ground snow load sk = 5.86 kN/m²

Structural analysis

The structural calculations for the technical room system are based on Eurocode 3 (EN 1993). The loads on the structure are measured according to Eurocode 1 (EN 1991-1-3) for a characteristic wind load qk,w = 0.585 kN/m² and a ground snow load sk = 2.5 kN/m². The structure is also designed for earthquake zone 3 according to EN 4149, EN 1998-1:2004. With additional equipment up to wind load zone 4 with terrain category I (qk,w = 1.064 kN/m²) or up to ground snow load sk = 5.86 kN/m².

Roof drainage

Roof drainage channels rain water to the frame running around the edge and drains it away on the short sides either to the left or the right.

Full description

New
SALE
bestseller
[[record.name]]
[[record.actionPrice]] [[record.price]] [[record.price]] Excl. VAT
Price on request

New
SALE
bestseller
[[record.name]]
[[record.actionPrice]] [[record.price]] [[record.price]] Excl. VAT
Price on request

Product description

  • The fire-rated solution for the safe operation of battery storage systems.
  • With classified fire protection from the inside and outside and therefore suitable for installation directly at the external wall of neighbouring buildings.
  • Integrated powerful storage system for very fast energy storage and release, optimised for permanent use in industry and commerce.
  • Individual adaptability to the required storage needs.
  • Tested, single-piece spill pallet with easily removable hot-dip galvanised grids (load capacity: 1000 kg / m²).
  • Fire protection panels with high insulation properties (thickness 100 mm, A class material, non-combustible).
  • Lockable, self-closing EI₂ 90-C fire-rated doors in accordance with EN 13501-2, tested in accordance with EN 1634-1
  • Surveillance and lighting technology - optionally also available with outdoor motion detector.
  • Structural analysis: to Eurocode 3 (DIN EN 1993) measured for a characteristic wind load with a dynamic pressure of qw = 0.585 kN/m² and a characteristic ground snow load of sk = 2.5 kN/m²; adequately dimensioned according to DIN 4149, EN 1998-1:2004 for earthquake zone 3. Available with additional equipment for up to wind load zone 4, terrain category I (qw= 1.064 kN/m²) and for up to ground snow load sk = 5.86 kN/m²

Structural analysis

The structural calculations for the technical room system are based on Eurocode 3 (EN 1993). The loads on the structure are measured according to Eurocode 1 (EN 1991-1-3) for a characteristic wind load qk,w = 0.585 kN/m² and a ground snow load sk = 2.5 kN/m². The structure is also designed for earthquake zone 3 according to EN 4149, EN 1998-1:2004. With additional equipment up to wind load zone 4 with terrain category I (qk,w = 1.064 kN/m²) or up to ground snow load sk = 5.86 kN/m².

Roof drainage

Roof drainage channels rain water to the frame running around the edge and drains it away on the short sides either to the left or the right.

Technical data

External dimensions W x D x H [mm] 3018 x 2784 x 2875
Storage area [m²] 7
Door position Short side
Door version hinged door
Door design 1-wing
Door hinge right
Fire resistance 90 minutes
120 minutes
Load capacity [kg/m²] 1000
Containment volume [l] 930
Internal room height [mm] 2500 mm
Storage capacity [kWh] 240 - 480
Weight without storage [kg] 2550

Documents

Do you need help?
We work hard to give you good advice.
Free Expert Advice 01952 811991

Mon - Thu: 08:30 - 17:00 Fri: 08:30 - 16:00

Menu
Log in
Your basketAdded to basket
Go to basket
We would be pleased to provide you with advice!

Give us a call or fill out the form and we will get back to you as soon as possible.

Mon - Thu: 08:30 - 17:00 | Fri: 08:30 - 16:00

Use code DEN10 at checkout for 10% off ALL of our catalogue products. Cannot be combined with other promotions, discounts or other special prices. Does not apply to open quotations.